Power distribution: VDD, ground, rails, straps, and IR drop

The power distribution network, or PDN, delivers current from the block's power connections to every standard cell.

Overview

Logic gates cannot function without physical power.

A chip does not receive ideal 1 and 0 values.

It receives electrical supply networks:

VDD / VPWR
ground / VGND

The PDN often has a hierarchy:

upper metal straps
      ↓
lower-level power distribution
      ↓
standard-cell rails
      ↓
transistor source/body connections

Signal routing and power routing are different jobs

Signal routing connects logic nets:

adder carry
mux select
result bit
clock

Power routing distributes current to a huge number of cells.

A PDN needs:

  • enough metal width
  • enough connections
  • appropriate pitch
  • adequate via connections
  • low enough resistance
  • acceptable voltage drop

IR drop

Any real conductor has resistance.

Voltage drop is approximately:

V = I × R

If a region draws current through too much resistance, the local supply voltage falls.

That can:

  • slow cells
  • worsen timing
  • reduce noise margin
  • cause functional failure in severe cases

Prerequisites

Steps

1. Find the PDN generation stage

RUN=$(ls -dt runs/* | head -1)

PDN_DIR=$(find "$RUN" -maxdepth 1 -type d \
  -name '*generatepdn*' | head -1)

echo "$PDN_DIR"

2. Open the design after PDN generation

librelane \
  --with-initial-state "$PDN_DIR/state_out.json" \
  --flow OpenInOpenROAD \
  "$RUN/resolved.json"

3. Hide signal layers selectively

Use the OpenROAD GUI layer controls.

Toggle metal layers on and off.

Find the repetitive VDD/ground structures.

Zoom in enough to distinguish:

power rails
power straps
vias

4. Follow one power path conceptually

Pick a standard-cell row and answer:

How does this row reach VDD?
How does it reach ground?
Which metal layers carry the larger PDN structures?
Where are vias used to change layers?

5. Understand vias

A wire on one metal layer does not automatically connect to a crossing wire on another layer.

A via is required for an electrical connection between layers.

In dense current paths, multiple vias may be used to reduce resistance and improve reliability.

6. Understand why upper metal is useful

Higher metal layers are often better suited to long-distance distribution because the process may provide different width/pitch/resistance options on those layers.

The exact layer usage is PDK- and flow-dependent.

7. Find the IR-drop report

The default Classic flow includes an OpenROAD IR-drop reporting step when enabled.

Find it:

find "$RUN" -maxdepth 1 -type d -iname '*irdrop*'

Inspect files:

IR_DIR=$(find "$RUN" -maxdepth 1 -type d -iname '*irdrop*' | head -1)
find "$IR_DIR" -maxdepth 2 -type f -printf '%p\n' | sort

Search reports:

grep -RniE "drop|voltage|worst|VDD|VPWR|VGND" "$IR_DIR" | head -100

8. Be careful interpreting tiny-design power

Our ALU is extremely small.

Its current profile is not representative of a CPU or large accelerator.

The goal here is to understand:

the analysis
the physical structure
the meaning of voltage drop

not to claim this block has solved full-chip power integrity.

9. Save screenshots

Save:

screenshots/pdn.png
screenshots/ir_drop.png

If the GUI provides an IR-drop heatmap for the loaded state, use it.

Results

Record:

PDN itemobservation
Main visible power layers
Standard-cell rail direction
Strap direction
Worst reported voltage drop
Any PDN warnings

Checklist

  • Can identify VDD/ground structures
  • Know what a via does
  • Know why PDN is not ordinary signal routing
  • Understand IR drop
  • Found the IR-drop report
  • Saved PDN evidence
  • Continued to page 17